Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Japanese Journal of Cardiovascular Surgery ; : 29-33, 2023.
Article in Japanese | WPRIM | ID: wpr-966089

ABSTRACT

We report a case of redo mitral valve replacement (MVR) for a Björk-Shiley Delrin valve implanted 47 years previously. A 71-year-old man initially underwent MVR for mitral regurgitation at our hospital at the age of 16 years. Following the operation, follow-up examinations were performed at the outpatient clinic and annual transthoracic echocardiogram findings showed only mild mitral regurgitation, with no adverse events noted. However, a transthoracic echocardiogram examination performed 45 years after the operation revealed mild to moderate mitral regurgitation, while dyspnea with exertion was also noted at that time. As part of a more detailed examination, transesophageal echocardiogram results showed moderate transvalvular leakage. Redo MVR was subsequently performed under the diagnosis of prosthetic valve dysfunction. Analysis of the explanted prosthetic valve revealed wear of the Delrin disk, and widening of the gap between the disk and strut, which were presumed to be the cause of transvalvular leakage. A half century has passed since introduction of the Björk-Shiley valve and the present is a rare case of valve malfunction. Presented here are related details, along with a review of existing literature and results of Björk-Shiley valve use at our hospital.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 731-737, 2023.
Article in Chinese | WPRIM | ID: wpr-996587

ABSTRACT

@#Objective     To analyze the clinical efficacy and survival outcome of totally thoracoscopic redo mitral valve replacement and evaluate its efficiency and safety. Methods     The clinical data of patients with totally thoracoscopic redo mitral valve replacement in Guangdong Provincial People’s Hospital between 2013 and 2019 were retrospectively analyzed. Survival analysis was performed using the Kaplan-Meier method. Univariate and multivariate Cox regression analyses were used to determine the risk factors for postoperative death. Results     There were 48 patients including 29 females and 19 males with a median age of 53 (44, 66) years. All the procedures were performed successfully with no conversion to median sternotomy. A total of 15, 10 and 23 patients received surgeries under non-beating heart, beating heart and ventricular fibrillation, respectively. The in-hospital mortality rate was 6.25% (3/48), and the incidence of early postoperative complications was 18.75% (9/48). Thirty-five (72.92%) patients had their tracheal intubation removed within 24 hours after the operation. The 1- and 6-year survival rates were 89.50% (95%CI 81.30%-98.70%) and 82.90%(95%CI 71.50%-96.20%), respectively. Age>65 years was an independent risk factor for postoperative death (P=0.04). Conclusion     Totally thoracoscopic redo mitral valve replacement is safe and reliable, with advantages of rapid recovery, reducing blood transfusion rate, reducing postoperative complications and acceptable long-term survival rate. It is worthy of being widely popularized in the clinic.

3.
Japanese Journal of Cardiovascular Surgery ; : 425-429, 2013.
Article in Japanese | WPRIM | ID: wpr-374614

ABSTRACT

We report a case of emergent redo-mitral valve replacement during pregnancy at 23 week and 4 days of gestation. A 23-year-old woman, who underwent mitral valve replacement with a bioprosthetic valve (Carpentier-Edwards Perimount<sup>®</sup> 27 mm) for infective endocarditis 5 years ago, was transferred to our hospital due to severe congestive heart failure. Echocardiography revealed structural valve deterioration of the mitral prosthesis and severe mitral stenosis. Emergent redo-mitral valve replacement with a bioprosthetic valve was performed to save the patient with top priority. Cardiopulmonary bypass was operated under normothermic, high flow, high pressure and pulsatile fashion. Fetal heart rate was continuously monitored during the operation. Although her baby was delivered vaginally just after operation weighing only 520 g, she was treated by the neonatologists successfully.

SELECTION OF CITATIONS
SEARCH DETAIL